OPTIWAVE 5400

Radar (FMCW) level transmitter for liquids in basic process applications

  • Continuous, non-contact level measurement in closed tanks or in the open air
  • 24 GHz radar, Horn or Drop antennas
  • Measuring range: 0…100 m / 328 ft
  • -50…+130°C / -58…+266°F; -1…16 barg / -14.5…232 psig

OPTIWAVE 5400

Radar (FMCW) level transmitter for liquids in basic process applications

  • Continuous, non-contact level measurement in closed tanks or in the open air
  • 24 GHz radar, Horn or Drop antennas
  • Measuring range: 0…100 m / 328 ft
  • -50…+130°C / -58…+266°F; -1…16 barg / -14.5…232 psig

Overview

The OPTIWAVE 5400 is a 2-wire 24 GHz radar (FMCW) level transmitter for liquids in basic process applications. It is particularly designed for continuous, non-contact level measurement in the chemical, petrochemical, power as well as oil and gas industry. It can be equipped with a PP Drop antenna for condensing atmospheres and corrosive media but features also Metallic Horn antennas. Due to its high dynamic range, the 24 GHz radar can measure distances up to 100 m / 328 ft.

Product features and options depend on device configuration: Contact us to make sure that your preferred functionality can be combined in one device.

  • 2-wire, loop-powered, with HART®7
  • PP Drop antenna:
    • Insensitive to condensation
    • Small beam angle (5° with DN150 / 6″ Drop antenna)
    • Ellipsoidal shape and smooth surface to minimise scaling
    • PP flange plate protection and cladded antenna extensions for corrosive media
    • New DN100 / 4″ Drop antenna for distances up to 80 m / 262.5 ft
  • 316L Metallic Horn antenna with optional purging system
  • TBM (Tank Bottom Management) ensures reliable measurement even in empty tanks:
    • dedicated algorithms to filter and compensate for irregular radar wave reflections that occur at tank bottom when the vessel is empty
    • allows for quick and easy commissioning of tanks regardless of their size, material or geometry
  • ±2 mm / ±0.08″ accuracy
  • Antenna extensions to suit any nozzle length
  • Empty tank spectrum function eliminates false reflections caused by tank internals
  • Large choice of flange and thread connections
  • Large, backlit LCD screen with 4-button keypad for operation with bar magnet; no need to open the housing cover
  • PACTware™, HART® DD and DTM provided free of charge with full functionality
  • Extensive device diagnostics acc. to NAMUR NE 107
  • SIL 2/3 certified for safety-related applications
  • 3-year warranty
Email